Arizona Administrative Code (Last Updated: November 17, 2016) |
Title 11. MINES |
Chapter 1. STATE MINE INSPECTOR |
Article 18. GASSY MINES |
Section R11-1-1801. Gassy mines operated in accordance with manda- tory standards |
Section R11-1-1802. Classifying mines gassy |
Section R11-1-1803. Flammable gases detected |
Section R11-1-1804. Men shall not smoke or carry smoking materials underground |
Section R11-1-1805. Use of open flames |
Section R11-1-1806. Welding or cutting underground |
Section R11-1-1807. Welding or cutting in atmospheres containing more than 1.0% of flammable gases |
Section R11-1-1808. Ventilation, main fans -- installation |
Section R11-1-1809. Ventilation, main fans -- operation |
Section R11-1-1810. Main intake and return air currents |
Section R11-1-1811. Single shafts used for intake and return |
Section R11-1-1812. When main fan fails or stops |
Section R11-1-1813. When there has been a failure of ventilation |
Section R11-1-1814. When ventilation is not restored in a reasonable time |
Section R11-1-1815. When main fan or fans have been shut down |
Section R11-1-1816. Booster fans -- operation |
Section R11-1-1817. Booster fans -- inspection, equipment |
Section R11-1-1818. Auxiliary fans -- operation |
Section R11-1-1819. Auxiliary fans -- inspection |
Section R11-1-1820. When auxiliary or booster fans slow down or stop |
Section R11-1-1821. Volume and velocity of the current of air |
Section R11-1-1826. Changes in ventilation |
Section R11-1-1827. Flammable gas in excess of 1.0% |
Section R11-1-1828. Flammable gas in excess of 1.5% |
Section R11-1-1829. Air containing 0.25% or more of flammable gas |
Section R11-1-1822. Quantity of air |
Section R11-1-1823. Measuring quantity of air at least once a week |
Section R11-1-1824. Permanently installed battery-charging and transformer stations |
Section R11-1-1825. Intake air |
Section R11-1-1830. Air inaccessible for inspection shall not be used for ventilation |
Section R11-1-1831. Abandoned areas shall be sealed or ventilated |
Section R11-1-1832. Seals shall be of substantial construction |
Section R11-1-1833. Sampling of atmosphere and measurement of pressure |
Section R11-1-1834. Crosscuts |
Section R11-1-1835. Crosscuts closed |
Section R11-1-1836. Line brattice or other suitable devices |
Section R11-1-1837. Brattice cloth |
Section R11-1-1838. Damaged brattices |
Section R11-1-1839. Crosscuts provided |
Section R11-1-1840. Entries or rooms shall not be started off entries |
Section R11-1-1841. Stoppings in crosscuts between intake and return airways |
Section R11-1-1842. Stoppings airtight |
Section R11-1-1843. Main ventilation |
Section R11-1-1844. Air locks shall be ventilated sufficiently |
Section R11-1-1845. Doors shall be kept closed |
Section R11-1-1846. Overcasts and undercasts |
Section R11-1-1847. Preshift examinations |
Section R11-1-1848. Qualified examiners |
Section R11-1-1849. Danger signs shall not be removed |
Section R11-1-1850. Examinations for dangerous conditions |
Section R11-1-1851. Prompt action to correct dangerous conditions |
Section R11-1-1852. Diesel-powered equipment |
Section R11-1-1853. Trolley wires and trolley feeder wires |
Section R11-1-1854. Only permissible equipment maintained |
Section R11-1-1855. Only permissible distribution boxes shall be used |
Section R11-1-1856. Electrical equipment |
Section R11-1-1857. Illumination |
Section R11-1-1858. Explosives not designated permissible by Bureau of Mines |
Section R11-1-1859. Granting approval of unpermissible explosives |
Section R11-1-1860. Blasts in gassy mines shall be initiated electrically |
Section R11-1-1861. Boreholes stemmed |
Section R11-1-1862. Examinations for flammable gas |
Section R11-1-1863. Shots or rounds shall not be fired |
Section R11-1-1864. Shots or rounds should be fired by qualified per- sons |