Section R11-1-1808. Ventilation, main fans -- installation
All data is extracted from pdf, click here to view the pdf.
-
Main fans shall be:
1. Installed on the surface.
2. Powered electrically from a circuit independent of the mine power circuit. Internal combustion engines shall be used only for standby power or where electrical power is not available.
3. Installed in fireproof housing provided with fireproof air ducts.
4. Offset not less than 15 feet from the nearest side of the mine opening and equipped with ample means of pres- sure relief unless:
a. The opening is not in direct line with forces which would come out of the mine should an explosion occur, and
b. Another opening not less than 15 feet nor more than 100 feet from the fan opening is equipped with a weak-wall stopping or explosion doors in direct line with the forces which would come out of the mine should an explosion occur.
5. Installed to permit prompt reversal of airflow.
6. Attended constantly, or provided with automatic devices to give alarm when the fans slow down to stop. Such devices shall be replaced so that they will be seen or heard by responsible persons.