Section R11-1-1184. Cable secured to hoist drum  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • The end of the rope at the drum shall make at least one full turn on the drum shaft, or a spoke of the drum in the case of a free drum, and shall be fastened securely by means of rope clips or clamps. There shall be three full turns of cable or rope on the hoisting drum when the cable or rope is extended to its maximum working length. This rule does not apply to friction hoists.

Historical Note

Adopted effective August 18, 1980 (Supp. 80-4).